LG mini split error codes ch 05

Meaning

The CH05 error code points to a communication error in the indoor/outdoor unit.

Possible causes

  1. The indoor unitis not receiving power.
  2. There is a power connection error in the indoor/outdoor unit (or communication line is not installed).
  3. Wiring errors could have occurred- wiring not done properly.
  4. The communication circuit parts in indoor/outdoor unit have fried.
  5. External noise- a communication error can also occur due to external noises

Basic Troubleshooting

  • Check power supply voltage to the outdoor/indoor units ( 230V ±10% ) and fix as necessary.
  • Correct the wiring or any loose connections.

LG mini split error code ch 07

Meaning

The indoor unit is in a different (cool/heat) operation mode from master indoor unit.

Possible fix

  • Change the mode -set indoor units (all) to cooling or heating to clear.
  • If not successful, try to turn off the mini split (at remote controller) then turn the unit back on.

LG mini split error code ch10

Meaning

Indoor unit fan may have locked up (due to failed fan motor operation). Indoor unit LEDs blinks once.

LG mini split error code ch 21

Meaning

DC peak error/IPM fault. If not, compressor DC voltage might be too high.

Potential causes

  1. Compressor has malfunctioned (short circuit).
  2. Compressor is down-to-earth.
  3. Inverter PCB could be faulty.
  4. IPM issue.

Possible fix

Test the inverter’s DC power circuit for over current- there is over current if it exceeds 14 Amps.

Check compressor windings –you want to test their resistance. Measure from U-V, V –W, and W-U (the values to be between 0.25 & 5 Ohms each).

Finally, check if compressor is down-to-earth- measure the resistance (from any compressor terminal) to earth point (pipework). The value should be exceeding 2 M Ohms.

Quick Note: The compressor may need replacing if these tests fail.

LG mini split error code 26

Meaning

The inverter compressor may be seized (because of trouble with its positioning system)

Suggested solution

Verify if the compressor is connected properly and then reset the unit.

You can now start up the unit once again and see if the compressor will start.

LG mini split error codes ch35

LG mini split error code ch35 Meaning

Low pressure sensor issue.

Possible causes

  1. Overload operation (due to the outdoor fan being constrained, screened, or blocked).
  2. Insufficient Refrigerant due to leakage.
  3. Pressure sensor is badly connected.
  4. The compressor sensor is faulty.
  5. The PCBA is defective.

Suggested fixes

  • Check for Refrigerant leakage.
  • Check and clear any blockages on your unit.

LG mini split error code ch 38

Meaning

  1. Electrical problem (e.g. unstable power supply)
  2. Low refrigerant- perhaps because of a leakage.

Proposed remedy

  • Reset power to your unit- simply unplug it (or shut the circuit breaker off) for 5 minutes or so then plug it back in.
  • Check the refrigerant level and have it refilled depending on your findings.

LG mini split error code ch 67

Meaning

Outdoor BLDC fan lockerror (Outdoor fan motor may be seized) or the rotation sensing circuit is faulty.

Probable fixes

  • Check the motor for both mechanical and electrical failure.
  • Replace PCB (if you found the fine).

Summary of common errors

Error codeMeaning
1Return air thermistor on LG mini split indoor unit disconnected/shorted out.
2Inlet pipe thermistor disconnected/shorted out (Indoor unit).
5Communication failure between indoor unit to the outdoor unit.
6Outlet pipe thermistor disconnected/shorted out(Indoor unit)..
9EEPROM error.
10Indoor unit fan locked up (-fan motor operation failed-).
12Middle pipe thermistor (indoor unit) disconnected/shorted out.
21DC peak error/IPM fault Or compressor DC voltage too high.
22Current transformer2(CT2) error/ AC input current too high.
23DC link voltage too low.
25Voltage to your system too low/too high.
26Inverter compressor seized up/not providing rotation.
27Prospective short circuit(PSC) issue error OR current to the inverter compressor between AC&DC converter circuit too high.
28Inverter compressor D.C. voltage too high.
29Inverter compressor amperage too high.
31Current to current transformer(CT) thermistor too low.
32Discharge pipe temperature (on inverter compressor) too high.
40Current transformer(CT) thermistor disconnected/shorted out.
41Discharge pipe thermistor (Inverter compressor) has disconnected/shorted out.
44Inlet air thermistor (Outdoor unit) disconnected/shorted out.
45Outdoor unit’s condenser coil middle thermistor disconnected/shorted out.
46Outdoor unit’s suction line thermistor disconnected/shorted out.
48Outdoor unit’s coil outlet (liquid-line) thermistor disconnected/ shorted out.
53Communication failure from the outdoor to indoor unit.
60Outdoor unit’s PCB E.E.P.R.O.M. check sum error.
61Outdoor unit condenser’s coil temperature too high.
62Outdoor unit’s inverter compressor’ PCB heat sink temperature_ too high.
63Condenser coil’s pipe thermistor temperature too low.
65Heat sink thermistor disconnected/shorted out.
67Outdoor BLDC_fan motor lock error.

LG Mini Split reset procedure

If everything fails to solve the error codes, resetting the unit could be helpful.

Here is how to reset your LG mini split:

  1. Turn off the LG split air conditioner.
  2. Unplug the AC and allow it to sit unplugged for 10 seconds (minimum).
  3. Plug your air con back in.
  4. Restart it by pressing the power button.

That’s it!

Wrapping it up

You now know what to check if trouble has occurred in your LG mini split system.

Use the above ideas to try DIY repairs before calling your local HVAC company- it could save you time and money!

More resources: Visit www.lg-dfs.com for more resources on troubleshooting LG mini split indoor error codes / LG mini split outdoor unit error codes. You can also reach out to LG DFS tech support (for those in Canada)

RELATED:

LG portable air conditioner compressor keeps shutting off

LG window ac control panel not working

How often should i drain my lg portable air conditioner?

LG portable air conditioner not blowing cold [Fixed]

LG mini split error codes and troubleshooting guide - MachineLounge (2024)

References

Top Articles
Latest Posts
Article information

Author: Clemencia Bogisich Ret

Last Updated:

Views: 5777

Rating: 5 / 5 (60 voted)

Reviews: 83% of readers found this page helpful

Author information

Name: Clemencia Bogisich Ret

Birthday: 2001-07-17

Address: Suite 794 53887 Geri Spring, West Cristentown, KY 54855

Phone: +5934435460663

Job: Central Hospitality Director

Hobby: Yoga, Electronics, Rafting, Lockpicking, Inline skating, Puzzles, scrapbook

Introduction: My name is Clemencia Bogisich Ret, I am a super, outstanding, graceful, friendly, vast, comfortable, agreeable person who loves writing and wants to share my knowledge and understanding with you.